[SUMMARY OF FINAL SUBMITTED VERSION]
PROGRESS REPORT BY PERMITTEE FOR 2020
Primary Owner:
MONTEREY COUNTY WATER RESOURCES AGENCY
Primary Contact:
Date Submitted:
03/30/2021
Application Number:
A032263A
Permit Number:
021376
MAX Direct Diversion Rate:
6
CFS
MAX Collection to Storage:
3000
AC-FT
Face Value:
3000
AC-FT
| 1. Compliance with Permit Terms and Conditions |
| I have reviewed my water right permit and I am complying with all terms and conditions |
Yes
|
| Description of noncompliance with terms and conditions |
|
| 2. Changes to the Project |
| Intake location has been changed |
|
| Description of intake location changes |
|
| Type of use has changed |
|
| Description of type of use changes |
|
| Place of use has changed |
|
| Description of place of use changes |
|
| Other changes |
|
| Description of other changes |
|
| 3-5. Permitted Project Status |
| Project Status |
Not Complete
|
| 5a. Construction work has commenced |
Yes
|
| 5b. Construction is completed |
Yes
|
| 5c. Beneficial uses of water has commenced |
Yes
|
| 5d. Project will be completed within the time period specified in the permit |
Yes
|
| 5e. Explanation of work remaining to be done |
Diversion and beneficial use of the maximum amount of water needed is dependent on natural conditions. Sufficient water has not been available to fully realize the maximum benefit to date. |
| 5f. Estimated date of completion |
12/31/2048 |
| 6. Purpose of Use
|
| Municipal |
110000
|
| Special Use Categories |
| C1. Are you using any water diverted under this right for the cultivation of cannabis? |
No |
| 7. Amount of Water Diverted and Used |
| Month |
Amount directly diverted
(Acre-Feet)
|
Amount diverted or
collected to storage
(Acre-Feet)
|
Amount used
(Acre-Feet)
|
| January |
0 |
0 |
0 |
| February |
0 |
0 |
0 |
| March |
0 |
0.15 |
0 |
| April |
0 |
0.05 |
0 |
| May |
0 |
141.14 |
0 |
| June |
0 |
198.21 |
0 |
| July |
0 |
85.09 |
0 |
| August |
0 |
0 |
0 |
| September |
0 |
108.38 |
69.2 |
| October |
0 |
13.8 |
234.83 |
| November |
0 |
35.63 |
234.83 |
| December |
0 |
34.68 |
78.27 |
| Total |
0 |
617.13 |
617.13 |
| Type of Diversion |
Diversion to Storage Only |
| Comments |
|
|
8. Water Diversion Measurement
|
| a. Required to measure as of the date this report is submitted |
Yes |
| b. Is diversion measured? |
Yes |
| c. An alternative compliance plan was submitted to the division of water rights on |
|
| d. A request for additional time was submitted to the division of water rights on |
|
| Measurement ID number | M024333 |
| This Device/Method was used to measure water during the current reporting period | Yes |
| M1. Briefly describe the measurement device or method | Magnetic Flowmeter |
| M2. Nickname | Blanco Drain Pump Station Flowmeter (FIT-171) |
| M3. Type of device / method | Flow meter (electromagnetic) |
| M4. Device make | Endress+Hauser |
| M5. Serial number | N6038A19000 |
| M6. Model number | 5W4C2F-AAALIP5DUA1K1B+CBZ1 |
| M7. Approximate date of installation | 01/22/2020 |
| M8. Additional info | Factory calibrated in ISO 17025 certified lab |
| M9. Approximate date the measuring device was last calibrated or the measurement method was updated | 07/26/2018 |
| M10. Estimated accuracy of measurement | 0.5% |
| M11. Description of calibration method | Flow - lab two-point calibration performed by manufacturer |
| M12. Describe the maintenance schedule for the device/method | |
| Information for the person who last calibrated the device or designed the measurement method |
| M13. Name | A. Leroy |
| M14. Phone number | +33 389 75 35 00 |
| M15. Email | |
| M16. Qualifications of the individual | |
| M17. License number and type for the qualified individual above and/or any other relevant explanation | The flowmeter was calibrated at the Endress+Hauser Flowtec AG facility in Cernay, France. The facility is an ISO 17025 certified testing/calibration lab. ISO 17025 is the international standard for testing and calibration facilities. |
| M18. Type of data recorder device / method | Other: SCADA system |
| M19. Data recorder device make | |
| M20. Data recorder serial number | |
| M21. Data recorder model number | |
| M22. Data recorder units of measurement | |
| M23. Frequency of data recording | |
| M24. Additional data recorder info | |
| M25. I am required to report my diversion or storage data by telemetry as of the date this report is submitted | No |
| M26. I report my diversion or storage date by telemetry to the following website | |
|
Measurement Data Files
|
| Measurement ID Number |
File Name |
Description |
Size |
|
No data files
|
|
9.
Maximum Rate of Diversion
|
|
Month
|
Rate of Diversion
(Cubic Feet Per Second)
|
|
January
|
0
|
|
February
|
0
|
|
March
|
5.78
|
|
April
|
0.71
|
|
May
|
6.89
|
|
June
|
6.49
|
|
July
|
6.81
|
|
August
|
0
|
|
September
|
6.95
|
|
October
|
6.76
|
|
November
|
6.64
|
|
December
|
2.86
|
| 10.Water Transfers
|
| 10a. Water transfered
|
No
|
| 10b. Quantity transfered (Acre-Feet)
|
|
| 10c. Dates which transfer occurred
|
/
to
/
|
| 10d. Transfer approved by
|
|
| Water Supply Contracts
|
| 10e. Water supply contract
|
No
|
| 10f. Contract with
|
|
| 10g. Other provider
|
|
| 10h. Contract number
|
|
| 10i. Source from which contract water was diverted
|
|
| 10j. Point of diversion same as identified water right
|
|
| 10k. Amount (Acre-Feet) authorized to divert under this contract
|
|
| 10l. Amount (Acre-Feet) authorized to be diverted in
2020
|
|
| 10m. Amount (Acre-Feet) projected for
2021
|
|
| 10n. Exchange or settlement of prior rights
|
|
| 10o. All monthly reported diversion claimed under the prior rights
|
|
| 10p. Amount (Acre-Feet) of reported diversion solely under contract
|
|
| 11. Storage |
| Reservoir name |
Spilled this year |
Feet below spillway at maximum storage |
Completely emptied |
Feet below spillway at minimum storage |
Method used to measure water level |
| Adjudicated Seaside Groundwater Basin |
No
|
0 |
No
|
0 |
Water stored in the Seaside Groundwater Basin |
| Credits Claimed |
|
Conservation |
Reclaimed Water Use |
Conjunctive Groundwater Use |
| Claimed? (Yes/No) |
No |
No |
No |
| January |
|
|
|
| February |
|
|
|
| March |
|
|
|
| April |
|
|
|
| May |
|
|
|
| June |
|
|
|
| July |
|
|
|
| August |
|
|
|
| September |
|
|
|
| October |
|
|
|
| November |
|
|
|
| December |
|
|
|
| Conservation Supporting Information |
| Description of conservation methods
|
| Description of baseline water use and time period
|
| Description of conservation calculation methods
|
| Conserved water used?
|
|
| Attachments |
| File Name |
Description |
Size |
|
Blanco PS Tech Memo 3-11-21.pdf
|
Technical Memorandum related to short term exceedances of maximum diversion rate.
|
103 KB
|
| Contact Information of the Person Submitting the Form |
| First Name |
Jason |
| Last Name |
Demers |
| Relation to Water Right |
Primary Owner of Record |
| Information on Certification and Signatory
|
| Name of Person Signing and Certifying the Report
|
Jason Demers
|
| Date of Signature
|
03/30/2021
|