[SUMMARY OF FINAL SUBMITTED VERSION]


REPORT OF LICENSEE FOR 2020

Primary Owner: WEST STANISLAUS IRRIGATION DISTRICT
Primary Contact:

Date Submitted: 06/16/2021

Application Number: A001987
License Number: 003957

Source(s) of Water POD Parcel Number County
TUOLUMNE RIVER Stanislaus
SAN JOAQUIN RIVER Stanislaus

MAX Direct Diversion Rate: 262.15 CFS
MAX Collection to Storage: 0 AC-FT
Face Value: 189790.7 AC-FT

Permitted Use(s) Acres Direct Diversion Season Storage Season
Irrigation 21666 01/01 to 12/31
1. Compliance with License Terms and Conditions
I have currently reviewed my water right license and I am complying with all terms and conditions Yes
Description of noncompliance with terms and conditions
2. Changes to the Project
Intake location has been changed
Description of intake location changes
Type of use has changed
Description of type of use changes
Place of use has changed
Description of place of use changes
Other changes
Description of other changes
3. Purpose of Use
Irrigation
Irrigated Crops
Multiple Crops Area Irrigated (Acres) Primary Irrigation Method
Alfalfa Yes 100 Surface (example: flood)
Almonds and Other Nuts No 13460.50 Sprinkler
Corn Yes 255 Surface (example: flood)
Fruit Yes 403 Surface (example: flood)
Grains (wheat, oat) Yes 202 Surface (example: flood)
Grapes No 674 Sub-surface
Legumes (peas, beans, peanuts) Yes 2995.50 Sub-surface
Tomatoes Yes 2162 Sub-surface
Tree Fruit (other) No 1821.50 Sprinkler
Vegetables Yes 160 Sub-surface
Other: Palms No 7 Sprinkler
Special Use Categories
C1. Are you using any water diverted under this right for the cultivation of cannabis? No
4. Amount of Water Diverted and Used
Month Amount directly diverted
(Acre-Feet)
Amount diverted or
collected to storage
(Acre-Feet)
Amount used
(Acre-Feet)
January 0 0 0
February 2619 0 1762
March 2918 0 1950
April 4981 0 4775
May 10992 0 9431
June 10107 0 9447
July 13246 0 11460
August 9149 0 7654
September    5261 0 4133
October 4367 0 3135
November 1679 0 1278
December 1484 0 1074
Total 66803 0 56099
Type of Diversion Direct Diversion Only
Comments
5. Water Diversion Measurement
a. Required to measure as of the date this report is submitted Yes
b. Is diversion measured? Yes
c. An alternative compliance plan was submitted to the division of water rights on
d. A request for additional time was submitted to the division of water rights on
Measurement ID numberM000848
This Device/Method was used to measure water during the current reporting periodYes
M1. Briefly describe the measurement device or method4- Path Ultrasonic Technology
M2. NicknameAccusonic Flow Meter
M3. Type of device / methodFlow meter (ultrasonic)
M4. Device makeAccusonic
M5. Serial number1736
M6. Model number7510 Plus
M7. Approximate date of installation08/09/2013
M8. Additional info
M9. Approximate date the measuring device was last calibrated or the measurement method was updated08/09/2013
M10. Estimated accuracy of measurement+/- 0.5%
M11. Description of calibration methodMeasurement of an ultrasonic pulse through the flow path over a specific distance.
M12. Describe the maintenance schedule for the device/methodEvery 3 Years
Information for the person who last calibrated the device or designed the measurement method
M13. NameEric Cadd
M14. Phone number508-273-9600
M15. Email
M16. Qualifications of the individualPerson trained and experienced in water measurement (for diversions of less than 100 acre-feet per year - no specific training is required; the person using any equipment and reporting the information must know how to use the equipment and submit correct information)
M17. License number and type for the qualified individual above and/or any other relevant explanation
M18. Type of data recorder device / methodData logger (digital)
M19. Data recorder device makeAccusonic Technology
M20. Data recorder serial number1736
M21. Data recorder model number7510 +
M22. Data recorder units of measurementCubic Feet
M23. Frequency of data recordingMore frequent than hourly
M24. Additional data recorder info
M25. I am required to report my diversion or storage data by telemetry as of the date this report is submitted
M26. I report my diversion or storage date by telemetry to the following website
Measurement Attachments
Measurement ID Number File Name Description Size
M000848 Measurement Certification Documents.pdf Measurement Certification 4 MB
Measurement Data Files
Measurement ID Number File Name Description Size
M000848 2020 WSID Diversion Data.xlsx 2020 WSID Diversion Datafiles 442 KB
6. Maximum Rate of Diversion
Month Rate of Diversion (Cubic Feet Per Second)
January 0
February 143.30
March 162.10
April 225
May 270
June 267.10
July 285.10
August 273.10
September 195.60
October 201
November 117
December 115.70
7. Water Transfers
7a. Water transfered No
7b. Quantity transfered (Acre-Feet)
7c. Dates which transfer occurred / to /
7d. Transfer approved by
Water Supply Contracts
7e. Water supply contract Yes
7f. Contract with USBR
7g. Other provider USBR
7h. Contract number 14-06-200-1072 LTR1
7i. Source from which contract water was diverted Delta-Mendota Canal
7j. Point of diversion same as identified water right No
7k. Amount (Acre-Feet) authorized to divert under this contract 50000
7l. Amount (Acre-Feet) authorized to be diverted in 2020 10000
7m. Amount (Acre-Feet) projected for 2021 2500
7n. Exchange or settlement of prior rights No
7o. All monthly reported diversion claimed under the prior rights No
7p. Amount (Acre-Feet) of reported diversion solely under contract 0
8. Storage
Reservoir name Spilled this year Feet below spillway at maximum storage Completely emptied Feet below spillway at minimum storage Method used to measure water level
           
Credits Claimed
Conservation Reclaimed Water Use Conjunctive Groundwater Use
Claimed? (Yes/No) Yes No No
January
February
March
April
May
June
July
August
September
October
November
December
Conservation Supporting Information
Description of conservation methods
Please refer to the document titled, "Summary of Water Conservation Efforts by West Stanislaus Irrigation District".
Description of baseline water use and time period
Please refer to the same document described in 11(a).
Description of conservation calculation methods
Please refer to the attached document titled, "2020 Summary of San Joaquin River Diversions Report for West Stanislaus Irrigation District".
Conserved water used? No
Additional Remarks
 
Attachments
File Name Description Size
2020 Summary of Water Diversions.pdf 2020 Summary of Water Diversions 186 KB
2020 Water Conservation Efforts.pdf 2020 Water Conservation Efforts 131 KB
Contact Information of the Person Submitting the Form
First Name Robert
Last Name Pierce
Relation to Water Right Company Representative
Information on Certification and Signatory
Name of Person Signing and Certifying the Report Robert Pierce
Date of Signature 06/16/2021