Primary Owner: TWIN OAKS IRRIGATION COMPANY
Primary Contact:

Date Submitted: 02/25/2019

Application Number: A004237
License Number: 001064

Source(s) of Water POD Parcel Number County
SAN JOAQUIN RIVER Stanislaus

MAX Direct Diversion Rate: 21.91 CFS
MAX Collection to Storage: 0 AC-FT
Face Value: 10560.4 AC-FT

Permitted Use(s) Acres Direct Diversion Season Storage Season
Irrigation 2212 02/15 to 10/15
1. Project Abandoned
The project has been abandoned and I request revocation of my water right license No
2. Compliance with License Terms and Conditions
I have currently reviewed my water right license and I am complying with all terms and conditions Yes
Description of noncompliance with terms and conditions
3. Changes to the Project
Intake location has been changed
Description of intake location changes
Type of use has changed
Description of type of use changes
Place of use has changed
Description of place of use changes
Other changes
Description of other changes
4. Purpose of Use
Irrigation
Irrigated Crops
Multiple Crops Area Irrigated (Acres) Primary Irrigation Method
Alfalfa No 1450 Surface (example: flood)
Corn Yes 110 Surface (example: flood)
Tomatoes No 140 Low-volume (example: micro-sprinkler, drip)
Other: Wheat No 740 Surface (example: flood)
Special Use Categories
C1. Are you using any water diverted under this right for the cultivation of cannabis? No
5. Maximum Rate of Diversion
Month Rate of Diversion (Cubic Feet Per Second)
January 0
February 21.91
March 0
April 21.91
May 21.91
June 21.91
July 21.91
August 21.91
September 21.91
October 21.91
November 0
December 0
6. Amount of Water Diverted and Used
Month Amount directly diverted
(Acre-Feet)
Amount diverted or
collected to storage
(Acre-Feet)
Amount used
(Acre-Feet)
January 0 0 0
February 300.65 0 300.65
March 0 0 0
April 184.5 0 184.5
May 807.1 0 807.1
June 667.6 0 667.6
July 753.95 0 753.95
August 743.8 0 743.8
September    532.6 0 532.6
October 83.3 0 83.3
November 0 0 0
December 0 0 0
Total 4073.5 0 4073.5
Type of Diversion Direct Diversion Only
Comments
Water Transfers
6d. Water transfered No
6e. Quantity transfered (Acre-Feet)
6f. Dates which transfer occurred / to /
6g. Transfer approved by
Water Supply Contracts
6h. Water supply contract No
6i. Contract with
6j. Other provider
6k. Contract number
6l. Source from which contract water was diverted
6m. Point of diversion same as identified water right
6n. Amount (Acre-Feet) authorized to divert under this contract
6o. Amount (Acre-Feet) authorized to be diverted in 2018
6p. Amount (Acre-Feet) projected for 2019
6q. Exchange or settlement of prior rights
6r. All monthly reported diversion claimed under the prior rights
6s. Amount (Acre-Feet) of reported diversion solely under contract
7. Water Diversion Measurement
a. Required to measure as of the date this report is submitted Yes
b. Is diversion measured? Yes
c. An alternative compliance plan was submitted to the division of water rights on
d. A request for additional time was submitted to the division of water rights on
Measurement ID numberM006987
This Device/Method was used to measure water during the current reporting periodYes
M1. Briefly describe the measurement device or methodFlowmeter
M2. NicknamePump #2
M3. Type of device / methodFlow meter (propeller)
M4. Device makeMcCrometer
M5. Serial number17-10813
M6. Model numberM1418
M7. Approximate date of installation09/01/2017
M8. Additional info
M9. Approximate date the measuring device was last calibrated or the measurement method was updated08/28/2017
M10. Estimated accuracy of measurement100%
M11. Description of calibration methodThis Calibration was performed at a Volumetric testing facility.
M12. Describe the maintenance schedule for the device/methodCheck annually, calibrate every 5 yrs.
Information for the person who last calibrated the device or designed the measurement method
M13. NameRobert Galusa
M14. Phone number951-652-6811
M15. Emailcustomerservice@mccrometer.com
M16. Qualifications of the individualCalifornia Licensed Professional Engineer (PE)
M17. License number and type for the qualified individual above and/or any other relevant explanation176785
M18. Type of data recorder device / methodData logger (digital)
M19. Data recorder device makeADCON
M20. Data recorder serial number864234
M21. Data recorder model numberA753
M22. Data recorder units of measurementAcre-Feet
M23. Frequency of data recordingHourly
M24. Additional data recorder info
M25. I am required to report my diversion or storage data by telemetry as of the date this report is submittedYes
M26. I report my diversion or storage date by telemetry to the following websiteapro.mccrometer.net
Measurement ID numberM006989
This Device/Method was used to measure water during the current reporting periodYes
M1. Briefly describe the measurement device or methodFlowmeter
M2. NicknamePump #3
M3. Type of device / methodFlow meter (propeller)
M4. Device makeMcCrometer
M5. Serial number17-10814
M6. Model numberM1418
M7. Approximate date of installation09/01/2017
M8. Additional info
M9. Approximate date the measuring device was last calibrated or the measurement method was updated08/28/2017
M10. Estimated accuracy of measurement100%
M11. Description of calibration methodCalibration was performed at a volumetric testing facility
M12. Describe the maintenance schedule for the device/methodCheck annually, calibrate every 5 yrs.
Information for the person who last calibrated the device or designed the measurement method
M13. NameRobert Galusha
M14. Phone number951 652-6811
M15. Emailcustomerservice@mccrometer.com
M16. Qualifications of the individualCalifornia Licensed Professional Engineer (PE)
M17. License number and type for the qualified individual above and/or any other relevant explanation176785
M18. Type of data recorder device / methodData logger (digital)
M19. Data recorder device makeADON
M20. Data recorder serial number864112
M21. Data recorder model numberA753
M22. Data recorder units of measurementAcre-Feet
M23. Frequency of data recordingHourly
M24. Additional data recorder info
M25. I am required to report my diversion or storage data by telemetry as of the date this report is submittedYes
M26. I report my diversion or storage date by telemetry to the following websiteapro.mccrometer.net
Measurement ID numberM006992
This Device/Method was used to measure water during the current reporting periodYes
M1. Briefly describe the measurement device or methodFlowmeter
M2. NicknamePump #4
M3. Type of device / methodFlow meter (propeller)
M4. Device makeMcCrometer
M5. Serial number17-10815
M6. Model numberM1418
M7. Approximate date of installation09/01/2017
M8. Additional info
M9. Approximate date the measuring device was last calibrated or the measurement method was updated08/28/2017
M10. Estimated accuracy of measurement99.9%
M11. Description of calibration methodCalibration was performed at a volumetric testing facility.
M12. Describe the maintenance schedule for the device/methodCheck annually, calibrate every 5 yrs.
Information for the person who last calibrated the device or designed the measurement method
M13. NameRobert Galusha
M14. Phone number951 652-6811
M15. Emailcustomerservice@mccrometer.com
M16. Qualifications of the individualCalifornia Licensed Professional Engineer (PE)
M17. License number and type for the qualified individual above and/or any other relevant explanation176785
M18. Type of data recorder device / methodData logger (digital)
M19. Data recorder device makeADCON
M20. Data recorder serial number864112
M21. Data recorder model numberA753
M22. Data recorder units of measurementAcre-Feet
M23. Frequency of data recordingHourly
M24. Additional data recorder info
M25. I am required to report my diversion or storage data by telemetry as of the date this report is submittedYes
M26. I report my diversion or storage date by telemetry to the following websiteapro.mccrometer.net
Measurement Attachments
Measurement ID Number File Name Description Size
No attachments
Measurement Data Files
Measurement ID Number File Name Description Size
M006987 P2 2018 report.csv Pump #2 1 MB
M006989 P3 2018 report.csv Pump #3 1 MB
M006992 P4 2018 report.csv Pump #4 1 MB
8. Storage
Reservoir name Spilled this year Feet below spillway at maximum storage Completely emptied Feet below spillway at minimum storage Method used to measure water level
           
Conservation of Water
9. Are you now employing water conservation efforts? Yes
Description of water conservation efforts Drainage recirculation to field irrigation. Acre ft. is estimated Have electrical records to verify pump running hrs.
10. Amount of water conserved 1250 Acre-Feet
11. I have data to support use reductions under this water right due to conservation efforts Yes
Water Quality and Wastewater Reclamation
12. During the period covered by this Report, did you use reclaimed water from a wastewater treatment facility, water from a desalination facility, or water polluted by waste to a degree which unreasonably affects the water for other beneficial uses? No
13. Amount of reclaimed, desalinated, or polluted water used
Conjuctive Use of Groundwater and Surface Water
14. During the period covered by this Report, were you using groundwater in lieu of available surface water authorized under your license? Yes
15. Amounts of groundwater used 3639 Acre-Feet
Additional Remarks
Did not divert much water Feb., March, and April due to wet conditions- season. 
Attachments
File Name Description Size
No Attachments
Contact Information of the Person Submitting the Form
First Name Daniel
Last Name Roberts
Relation to Water Right Other: Agent
Information on Certification and Signatory
Name of Person Signing and Certifying the Report Daniel L Roberts
Date of Signature 02/25/2019